Skip to main content

International Journal of Interdisciplinary Research

Table 6 Individual errors between experimental and predicted values of air permeability & moisture vapour transmission rate

From: Development and comparison of artificial neural network and statistical model for prediction of thermo-physiological properties of polyester–cotton plated fabrics

Sample code

Experimental air permeability (cm3/cm2/s)

Predicted air permeability (cm3/cm2/s)

Error % \(\left( {\frac{{\left| {E - P} \right|}}{E}} \right)\) *100

Experimental moisture vapour transmission rate (g/m2/24 h)

Predicted moisture vapour transmission rate (g/m2/24 h)

Error % \(\left( {\frac{{\left| {E - P} \right|}}{E}} \right)\) *100

PETC3

156.13

152.48

2.34

5.99

6.26

4.55

PETC6

113.13

126.38

11.71

5.10

4.81

5.77

PETC10

168.20

154.89

7.91

6.13

6.69

9.12

PETC15

155.00

148.97

3.89

5.99

6.44

7.45

PETC27

96.50

90.46

6.26

5.15

5.56

8.00

PETC30

133.00

130.94

1.55

5.98

6.27

4.78

PETC32

95.00

81.44

14.28

3.66

4.64

26.92

PETC35

131.00

128.52

1.89

5.82

5.86

0.60

PETC41

59.80

55.70

6.85

3.05

3.07

0.78

PETC45

127.30

105.66

17.00

5.01

5.24

4.53

Mean absolute percentage error

  

7.37

  

7.25